RDL ST-LCR3 Logic Controlled Relay, Dual Alternate Pulse

The ST-LCR3 makes two momentary pulses from one control signal: a START PULSE when the signal first goes active and an END PULSE when it goes inactive. Both last about 250 ms. Each pulse output has an open-collector SLAVE terminal and a set of relay contacts, so it can drive RDL modules or equipment that needs a contact closure.

Terminal 1 is pulled up to +5 Vdc and goes active when a closure or open-collector pulls it to ground; terminal 3 is pulled to ground and goes active on +3.3 to +24 Vdc. Either input can be used. The module needs ground-referenced 24 Vdc. RDL recommends its PS-24AS power supply (PS-24AX outside the USA), not included.

  • Inputs (2)Logic High or Logic Low
  • Maximum Switching Power60 W (220 Vdc, 125 Vac, 2 A)
  • Power RequirementGROUND-REFERENCED
  • Switching ContactsSingle Pole Relay Contacts (2)
  • Ambient Operating Environment0° C to 55° C
Part NumberST-LCR3
Inputs (2)Logic High or Logic Low (Low = ground, High = 3.3 Vdc to 24 Vdc)
Outputs (2)Open collector @ 25 mA suitable to drive indicators or slave LCRs.
Switching ContactsSingle Pole Relay Contacts (2)
Maximum Switching Power60 W (220 Vdc, 125 Vac, 2 A)
Power RequirementGROUND-REFERENCED, 24 Vdc @ 100 mA (assuming 20 mA max load at SLAVE output)
Ambient Operating Environment0° C to 55° C