RDL logo
Shop All RDL

RDL ST-LCR1 Logic Controlled Relay, Momentary

The ST-LCR1 adds double-pole, double-throw dry contacts to nearly any control signal. It works momentarily: the relay closes while the control signal is present and opens when the signal goes away. An LED shows when the relay is closed.

Drive it by grounding the SLAVE terminal from a push-button, switch or another unit's open-collector output, with 3.5 to 12 Vdc on the 5V+ input, or with 12 to 35 Vdc on the 24V+ input. The SLAVE terminal can also drive indicators or more relays. It runs from ground-referenced 24 Vdc. RDL recommends its PS-24AS power supply (PS-24AX outside the USA), not included.

  • Maximum Switching Power60 W (220 Vdc, 125 Vac, 2 A)
  • Power RequirementGROUND-REFERENCED, 24 Vdc @ 50 mA *
  • Shipping Weight0.185 lbs.
  • Switching ContactsDouble-pole, double-throw
  • Ambient Operating Environment-10° C to 55° C
Part NumberST-LCR1
Switching ContactsDouble-pole, double-throw
Maximum Switching Power60 W (220 Vdc, 125 Vac, 2 A)
Control OutputSLAVE terminal open-collector @ 25 mA suitable to drive indicators or slave LCRs
Power RequirementGROUND-REFERENCED, 24 Vdc @ 50 mA *; * Assumes 20 mA max load at SLAVE output
Ambient Operating Environment-10° C to 55° C
Shipping Weight0.185 lbs.