RDL TX-AVX Automatic Video Switch, 2x1, BNC
The TX-AVX watches a primary video feed and switches its output to a secondary source when that feed is lost. While valid NTSC or PAL sync is present on INPUT, an RF relay connects INPUT to OUTPUT; without it, or if the module loses power, AUX INPUT goes to the output. Detection keys on sync, ignores 50 and 60 Hz hum, and reads signals as weak as 0.5 V p-p.
Video connects on BNC jacks, and the output must feed a 75 Ohm terminated load. When video is present the SLAVE terminal switches to ground, so the module can also serve as a video-present detector, for example with an RDL BZR alert module. It runs from 12 to 33 Vdc or 12 to 24 Vac. RDL recommends its PS-24AS power supply (PS-24AX outside the USA), not included.
- InputsBNC, Ground-referenced
- Input Level0.5 V p-p video to 1 V p-p video
- OutputBNC
- Maximum Switching Power60 W (220 Vdc, 125 Vac, 2A)
- Power RequirementGROUND-REFERENCED, 12 to 33 Vdc or 12 to 24 Vac @ 100 mA
| Part Number | TX-AVX |
|---|---|
| Inputs | BNC, Ground-referenced |
| Input Level | 0.5 V p-p video to 1 V p-p video |
| Output | BNC, Ground-referenced (Output must be terminated with 75 Ω load) |
| Slave Output | Switches to ground on valid input signal |
| Relay Contacts | Single-Pole/Single-Throw |
| Maximum Switching Power | 60 W (220 Vdc, 125 Vac, 2A) |
| Power Requirement | GROUND-REFERENCED, 12 to 33 Vdc or 12 to 24 Vac @ 100 mA |