RDL logo
Shop All RDL

RDL TX-MVX Remote Controlled Video Switch, 2x1, BNC

The TX-MVX is a 2x1 video switch run by a manual switch or an open-collector output. VIDEO A is normally connected to COMMON; when the TRIG terminal is pulled to ground, VIDEO B connects instead. The RF relay works in either direction, routing one source to one of two destinations or choosing between two sources for one destination.

Video connects on BNC jacks. The controlling switch can sit away from the module, and the open-collector SLAVE terminal on many RDL modules, or relay contacts on other equipment, can also trigger it. It runs from ground-referenced 24 Vdc at 30 mA. RDL recommends its PS-24AS power supply (PS-24AX outside the USA), not included.

  • Input(s), Output(s)BNC, ground-referenced
  • TRIG Input Current2 mA
  • TRIG Input Threshold2 Vdc
  • Power RequirementGROUND-REFERENCED, 24 Vdc @ 30 mA
  • Shipping Weight0.3 lbs.
Part NumberTX-MVX
Input(s), Output(s)BNC, ground-referenced
TRIG Input Current2 mA
TRIG Input Threshold2 Vdc
Power RequirementGROUND-REFERENCED, 24 Vdc @ 30 mA
Ambient Operating Environment-10° C to 55° C
Shipping Weight0.3 lbs.