RDL TX-VCR Video Controlled Relay, BNC
The TX-VCR gives a control signal based on whether valid video is present. It detects NTSC or PAL sync, ignores 50 and 60 Hz hum, and responds to signals as weak as 0.5 V p-p. When it sees video the relay contacts close, and with both normally-open and normally-closed contacts it can work as a video-present or a video-loss detector. A front SYNC LED lights while valid video is detected.
Video connects on a BNC INPUT and a LOOP OUT jack. Insert it in a line with the loop-through feeding a terminated load, or put it at the end of a line with the supplied 75 Ohm terminator on LOOP OUT. For an audible loss-of-video alarm, wire it to an RDL BZR. It runs from 12 to 33 Vdc or 12 to 24 Vac. RDL recommends its PS-24AS power supply (PS-24AX outside the USA), not included.
- DimensionsHeight: 1.4 in 3.6 cm; Length: 3.0 in 7.6 cm
- InputBNC, ground-referenced
- Input Level0.5 V p-p video to 1 V p-p video
- OutputLOOP OUT , BNC
- Maximum Switching Power60 W (220 Vdc, 125 Vac, 2A)
| Part Number | TX-VCR |
|---|---|
| Input | BNC, ground-referenced |
| Input Level | 0.5 V p-p video to 1 V p-p video |
| Output | LOOP OUT , BNC, ground-referenced (Output must be terminated with 75 Ω connected load or with 75 Ω terminator supplied) |
| Control Output | N/O or N/C relay contacts |
| Relay Contacts | Single-pole/double-throw |
| Maximum Switching Power | 60 W (220 Vdc, 125 Vac, 2A) |
| Power Requirement | GROUND-REFERENCED, 12 to 33 Vdc or 12 to 24 Vac, @ 75 mA |
| Dimensions | Height: 1.4 in 3.6 cm; Length: 3.0 in 7.6 cm; Width: 1.2 in 3.0 cm |