Crestron logo
Shop All Crestron

Crestron DIN-THSTAT Heating, Cooling, and Relative Humidity Thermostat, DIN Rail Mount

The Crestron DIN-THSTAT is a Heating, Cooling, and Relative Humidity Thermostat, DIN Rail Mount. It snaps onto a standard 35 mm DIN rail inside an electrical enclosure, so the lighting and control hardware for a floor or a residence assembles as a panel instead of a rack.

Power consumption is 3 W (125 mA @ 24VDC). Mounting: 35 mm DIN EN 60715 rail mount, DIN 43880 form factor for enclosures with 45 mm front panel cutout, occupies 9 DIN module spaces (162 mm). Housing: Plastic. Cresnet carries both power and data to the module over a four-conductor run, and the panel reports to a Crestron control processor or to Crestron Home.

  • Size1.80 in. diagonal
  • INTERFACEFor future use
  • Measurement Range (Supplied by Remote Sensor): Humidity0% to 100% RH
  • Resolution176 x 220
  • Setpoint Range: Humidity5% to 90% RH
Indoor Temperature32° to 110°F (0° to 43°C)
Outdoor Temperature-40° to 170°F (-40° to 77°C); NOTE: Outdoor temperature measurement is -30° to 120°F (-34° to 49°C) if thermistor sensors are used.
Measurement Range (Supplied by Remote Sensor): Humidity0% to 100% RH
Temperature Tolerance±1ºF (±0.5ºC)
Humidity Tolerance± 5.0% RH
Auto38° to 99°F (3° to 37°C)
Heat38° to 89°F (3° to 32°C)
Cool59° to 99°F (15° to 37°C)
Setpoint Range: Humidity5% to 90% RH
Setpoint RangeNOTE: The setpoint range can be decreased during device configuration.
Relay Rating1A @ 24VAC or 30VDC
Power Consumption3 W (125 mA @ 24VDC)
Cresnet® WiredControl system integration or networking
Keypad(1) 5-way navigation pad; For menu navigation and temperature/humidity adjustments
HOME(1) pushbutton; Returns to the previous screen or the home screen
BACK(1) pushbutton; Steps menu back one level
TypeRGB LCD
Size1.80 in. (46 mm) diagonal
Resolution176 x 220
FunctionFront panel display to view temperature and humidity settings; Used for local configuration
Y1, Y2, Y3(1) Compressor stage 1, 2, and 3
G(1) Fan relay
B(1) Active in non-cool modes
O(1) Active in cool mode
RC(1) Reference cool
RH(1) Reference heat
W1, W2, W3(1) Heat stage 1, 2, and 3
HUM(1) Humidity call switch power
AUX1, AUX2(2) Output relay to interface with other HVAC devices
AUX-IN(1) Signal from HVAC state sensing or other custom programming
TS1, TS2, G(2) Remote sensor inputs and (2) ground inputs; For indoor remote temperature sensor (CHV-RTS), remote slab sensor (CHV-RSS), remote temperature and humidity sensors (CHV-RTHS), and 10k thermistors (all sensors and thermistors are sold separately); Each temperature sensor requires a dedicated low-capacitance twisted pair wire (<7 nF per run) and supports a wire length of 500 ft (152 m) using CAT5. Thermostat wire is not recommended, but may be used if necessary at lengths up to 100 ft (30 m).
TS3, G(1) From outdoor remote temperature sensor and (1) ground; Also compatible with 10k thermistors. All sensors and thermistors are sold separately. (1) Remote sensor input and (1) ground input; For outdoor remote slab sensor (CHV-RSS) and 10k thermistors sensors and thermistors are sold separately); Each temperature sensor requires a dedicated low-capacitance twisted pair wire (<7 nF per run) and supports a wire length of 500 ft (152 m) using CAT5. Thermostat wire is not recommended, but may be used if necessary at lengths up to 100 ft (30 m).
24 Y Z G(2) 4-pin detachable terminal blocks; Cresnet secondary port with hardwire parallel pass-through
USB(1) Micro B female, USB 2.0 computer console port for firmware download
INTERFACEFor future use
Temperature32° to 104°F (0° to 40°C)
Environmental: Humidity10% to 90% RH (noncondensing)
Heat Dissipation10 BTU/hr maximum; For indoor use only
HousingPlastic
Mounting35 mm DIN EN 60715 rail mount, DIN 43880 form factor for enclosures with 45 mm front panel cutout, occupies 9 DIN module spaces (162 mm)
Height3.68 in. (94 mm)
Width6.33 in. (161 mm)
Depth2.34 in. (60 mm)
Weight13 oz (363 g)
ComplianceFCC Part 15 Class B, IC Class B, CE
SourceFull specifications on crestron.com