RDL D-RLC3 Remote Level Control with Four Preset Levels
The D-RLC3 gives users four fixed level choices instead of a free-turning knob. HIGH puts the VCA at maximum gain; NORM, LOW and MIN are each set by the installer with trimpots on the sides of the unit, which are hidden once it is installed. At power-up it defaults to NORM, and MIN can be set all the way to off.
It connects directly to RDL modules with a 0 to 10 Vdc control input that use an external 10 kΩ resistive control, such as the ST-VCA3, RU-VCA2A and RU-VA6A, and shares the VCA's power supply. Wiring is on a detachable terminal block, and it mounts in a standard US electrical box or an RDL WB- or SMB- series box (cover plate sold separately). It draws ground-referenced 24 Vdc; RDL recommends the PS-24AS (USA) or PS-24AX (international) supply. RDL makes it in white, black and stainless steel.
- InterfaceDirect connection with RDL modules using 0 to 10 Vdc
- ConnectionsDetachable terminal block
- Power RequirementGround-referenced, 24 Vdc @ 30 mA
- High10 kOhm, 0 dB
- NormAdjustable, -3 dB to -30 dB
| Part Numbers | D-RLC3 (White), DB-RLC3 (Black), DS-RLC3 (Stainless Steel) |
|---|---|
| Interface | Direct connection with RDL modules using 0 to 10 Vdc, 10 kΩ resistive control (see ST-VCA3, RU-VCA2) |
| High | 10 kOhm, 0 dB |
| Norm | Adjustable, -3 dB to -30 dB |
| Low | Adjustable, -5 dB to -40 dB |
| Min | Adjustable, -10 dB to Off |
| Connections | Detachable terminal block |
| Power Requirement | Ground-referenced, 24 Vdc @ 30 mA |
| Mounting | Mounts in standard US electrical box, RDL WB- or SMB- series boxes; cover plate available separately. |