19", 3 RU break out panel, I/O connector transition assembly. Provides a convenient interface between a SAP-1626 (25 pair 50-pin) and up to 20 user stations or strings of stations (3 pin XLR male).
I/O Connector Translation Assembly
The BOP-220 Break out panel interfaces with the SAP-1626 and the TW Intercom user stations. It is a passive routing device (no electronics) which converts the two 50-pin connectors from the SAP-1626 to 20 XLR-type 3-pin male connectors for direct connection to the user stations. All 20 user station lines connect to this central point. Packaging
The BOP-220 requires three rack units and mounts directly behind the SAP-1626; it is inset from the rear rack rails to allow for cable connections. Each connector on the BOP-220 is numbered with respect to its pair of thumbwheel switches on the SAP- 1626. This allows for easy system connections as well as rapid disconnection in the event of a faulty line.
Color Copper Depth 5" (127 mm) Height 5.25" (133.4 mm) Weight 2.43 lbs (1.1 kg) Width 19" (482.6 mm)