Crown Audio CTs Series - Multi-Channel

Click here for more info Crown Audio CTs 4200
G&G Price: $1,754
Want a better price?
CTs 4200 Amplifier
Crown Audio CTs 8200
G&G Price: $3,409
Want a better price?
CTs 8200 Amplifier

Accessories:
IQ-MC4
IQ Module for CTs 4200 $384
IQ-MC8
IQ Module for CTs 8200 $384
VCA-MC4
VCA Module for CTs 4200 $129
VCA-MC8
VCA Module for CTs 8200 $129
1-VCAP
1-Gang Panel with 1 VCA Channel Volume Control $60
4-VCAP
2-Gang Panel with 4 VCA Channel Volume Controls $180
T-170V
This is a rack-mountable panel with 4 autoformers that provide impedance
matching between amplifier outputs and "constant voltage" loudspeakers.
It provides 100V output in Dual mode when used with CTs 600, CTs
1200, CTs 4200 and CTs 8200 amplifiers, and allows other amplifiers
without direct Constant-Voltage capability to be easily integrated into
distributed systems
$84
TP-170V
A single autoformer that provides the same impedance matching capability
as the TP-170V, for a single channel. The T-170V is ready to be mounted
in a rack, or enclosed in a metal box.
$241

Description:
Building on the foundation of the Com-Tech® Series, Crown’s CTs Series offers new flexibility and value for installed sound applications. The Com-Tech Series were the first to offer independent selection of high and low-impedance operation for a specific channel, and CTs Series amplifiers continue that tradition, with power levels and features carefully chosen to perfectly integrate into fixed install design requirements. For added flexibility, the CTs Series includes both dual-channel and multi-channel models.

All models in the CTs Series feature Crown’s new Switching Power Supply for lighter weight, and all models are also compatible with the IQ System®. Multi-channel models accept new MC accessory modules that provide enhanced control, monitoring, and system integration.

The CTs multi-channel amps feature FIT (Fault Isolation Topology), which isolates channel-specific faults and prevents them from affecting remaining channels. If a CTs multi-channel amp is powering multiple zones, and a channel fails, the other zones continue to operate.

In a profession where unplanned service calls quickly wipe out profits, the CTs Series amplifiers are designed to be the most reliable amplifiers you can install.

Features:
  • New Crown Switching Power Supply for reduced weight.
  • High power-density, with four channels (CTs 4200) or eight channels (CTs 8200) in a 3U chassis.
  • Selectable constant-voltage (70V/100V) or lowimpedance (4/8 ohm) operation for each channel pair. (Channel pair must be operated in Bridge mode for 100V output).
  • FIT (Fault Isolation Topology) circuitry isolates faults within affected channels.
  • TLC protection circuitry protects the amplifier from excessive heat by subtly and dynamically reducing the gain only when necessary to reduce heat levels.
  • Accepts new MC accessory modules that tailor the amplifier to suit specific applications. Modules available for remote VCA level control and IQ System® Control.
  • A fixed 35-Hz (70-Hz in CTs 4200) high-pass filter per channel pair is automatically inserted when the mode switch is set to either of the constant-voltage settings. The high-pass filter corner frequency in the CTs 8200 can be set to 70 Hz, or bypassed, with a service option.
  • Comprehensive array of indicators including Power and Data, along with Bridge, Ready, Signal, Clip, Thermal and Fault for each channel, provide accurate diagnostics.
  • Blue Power Indicator flashes if the amplifier shuts off due to an under/over voltage condition on the AC mains.
  • Advanced protection circuitry guards against: shorted outputs, open circuits, DC, mismatched loads, general overheating, under-/over-voltage, high-frequency overloads and internal faults.
  • Proven Crown AB+B Multi-Mode® output topology.
  • Continuously-variable fans optimize cooling efficiency.
  • Three Year, No-Fault, Fully Transferable Warranty completely protects your investment and guarantees its specifications.
  • Crown’s advance-replacement Profit Protection Plan provides quick, no-questions-asked replacement of covered amps should they fail at any time up to 6 months following date of installation.

Specifications:
  • Frequency Response (at 1 watt, 20 Hz - 20 kHz): ±0.5 dB.
  • Phase Response (at 1 watt, 10 Hz - 20 kHz): ±35°.
  • Signal to Noise Ratio below rated power (20 Hz to 20 kHz): 100 dB unweighted.
  • Total Harmonic Distortion (THD) at 1 watt, from 20 Hz to 20 kHz: < 0.05%.
  • Intermodulation Distortion (IMD) 60 Hz and 7 kHz at 4:1, from 163 milliwatts to full bandwidth power: < 0.05% (typical).
  • Damping Factor: 10 Hz to 400 Hz: >180.
  • Crosstalk (below rated power, 20 Hz to 1 kHz): > 80 dB.
  • Common Mode Rejection (CMR) (20 Hz to 1 kHz): > 50 dB.
  • DC Output Offset (shorted input): < ±5 mV.
  • Input Impedance (nominal): 20 kilohms balanced, 10 kilohms unbalanced.
  • Maximum Input Level (before input compression): + 20 dBu.
  • Load Impedance: (Note: Safe with all types of loads)
    • Stereo: 4/8 and 25 ohms (70V)
    • Bridge Mono: 8/16 and 50 ohms (100V)
  • Voltage Gain (at maximum level setting), 1.4V sensitivity:
    • 4/8 Ohm Operation: 20:1 (26 dB);
    • 70V Operation: 50:1 (34 dB)
    • 100V Operation: 71.4:1 (37 dB)
  • Required AC Mains: 120V 60 Hz, 220/230/240V/50 Hz.
  • Power Draw at Idle (120VAC mains, all channels in 4/8 ohm mode): 58W.
  • Power Draw at Idle (120VAC mains, all channels in 70V mode): 77W.
  • Cooling: Continuously variable speed forced air, front-to-back airflow.
  • Dimensions (Width, Height, Depth):
    CTs 4200: 19 in. (48.3 cm) W x 3.5 in. (8.9 cm) H x 16.25 in. (41.3 cm) D. CTs 8200: 19 in. (48.3 cm) W x 5.25 in. (13.3 cm) H x 16.25 in. (41.3 cm) D.
  • Weight (Net, Shipping):
    CTs 4200: 27 lb 8 oz (12.5 kg), 32 lb (14.5 kg)
    CTs 8200: 36 lb 6 oz (16.5 kg), 47 lb (21.3 kg).
    Front Panel Controls and Indicators
  • Bridge Mode Indicator: Yellow LED, one per channel pair, illuminates when the channel pair’s Mode Switch is set to the "Bridge" position. If Mode switch is changed while amplifier is powered up, Bridge LED will flash, indicating that the amplifier must be powered off and on to reset the Mode.
  • Ready Indicator: Green LED, one per channel, illuminates when the channel is initialized and ready to produce audio output.
  • Signal Indicator: Green LED, one per channel, illuminates to indicate the presence of input signals above –40 dBu.
  • Clip Indicator: Red LED, one per channel, illuminates when the THD of the channel’s output signal rises to a level typically considered as the onset of audible clipping. The Clip Indicator also will illuminate during Thermal Level Control (TLC) or input overload.
  • Thermal Indicator: Red LED, one per channel, flashes when a state of thermal stress or overload has caused the channel to shut down. If the power supply goes into thermal overload, all channel LEDs will flash.
  • Fault Indicator: Red LED, one per channel, flashes when a fault condition has occurred in the channel.
  • Ventilation Grille: Front-to-rear forced airflow.
  • Data Indicator: Yellow LED indicates IQ Loop data activity (if the amplifier is equipped with an IQ-MC module, and connected to an IQ Loop).
  • Power Indicator: Blue LED indicates amplifi er has been turned on and AC power is available. Indicator also fl ashes if the amplifier shuts off due to an under-/over-voltage condition on the AC mains.
  • Power Switch: Amplifier is on when the switch is in the IN position.
    Back Panel Controls and Connectors
    AC Power Cord Connector: IEC inlet, type 320; 100/120VAC units: 15A; 220/230/240VAC units: 10A. Voltage is indicated above IEC inlet. Output Connectors: One four-pole terminal strip for every two channels with touch-proof cover. Accepts up to 10 AWG terminal forks. Accessory Panel: CTs 4200 accepts an optional IQ-MC4A or VCA-MC4A module. CTs 8200 accepts an optional IQ-MC8 or VCA-MC8 module. Channel Level Controls: One 21-position detented rotary potentiometer per channel, ranging from infi nity (–70 dB) to 0 dB attenuation. Input Connectors: Removable Phoenix-style barrier connectors for balanced input. Mode Switch: Used on each consecutive pair of channels, this four-position switch is used to select the amplifi er’s mode of operation: Dual 8/4 ohms, Dual 70V, Bridge-Mono 16/8 ohms, and Bridge-Mono 100V. Cooling Vents: Front-to-rear forced airfl ow. Options Control Modules: IQ-MC4A: IQ module for CTs 4200A; VCA-MC4A: VCA module for CTs 4200A. IQ-MC8: IQ module for CTs 8200; VCA-MC8: VCA module for CTs 8200. Wall-mount level control panels for use with VCA module: 1-VCAP: Single-gang panel with 1 VCA channel volume control; 4-VCAP: Two-gang panel with 4 VCA channel volume controls. T-170V: This is an autoformer that allows 100V output from the amplifi er, and allows other ampli- fi ers without direct constant voltage output to be easily integrated into distributed systems. TP-170V: This is a rack-mountable panel with four autoformers as described above. Protection Systems Thermal Level Control (TLC): If an amplifi er channel starts to overheat, the TLC circuit will engage that channel’s input compressor. By compressing the input, the amplifi er will not generate as


If you haven't noticed - we've moved!

Note our new address and fax number!

G&G Technologies
280 North Midland Avenue
Zuckerberg's Industrial Park, Bldg. F
Saddle Brook, NJ 07663

Search:
all words any words exact phrase

800-422-2920    Fax: 201-791-1401     Send us email     AOL Instant Message Us!


Driving to G&G    Sales Terms & Conditions    Privacy Statement

Not responsible for typographical errors.
©1988-2008 G&G Technologies, Inc. All rights reserved.